Oil Contaminants Solution

Filtration Oil Turbine Generator

Image Description

Manufacture

Initial Client Problem

High water content and oil contamination resulted in corrosion in the main storage tank. The client used ISO VG 46 oil, with a target cleanliness level of 18/16/13 according to ISO 4406 or NAS 7 standards.

Our Solution

TeknoFluida's technical team promptly responded by implementing a filtration solution using the MFU-100 unit to eliminate contaminants. The filtration was executed in two phases: the first targeting oil stored in the IBC tank, followed by treatment of the oil in the main tank. Each stage required approximately 18 hours to complete. This process successfully reduced the oil’s cleanliness level from 22/20/17 to 18/16/11 in accordance with ISO 4406 standards.